Seal Failures in Hot Wort Applications

In our dealings with brewers, we have found many are unhappy with the seal life of the pumps used to transfer hot wort. We have found that almost invariably, the pump has an internal seal which consists of a polymer rotary seal riding against a stainless steel stationary surface. We have come to the conclusion (solely our opinion) that many of these seal failures are due to the following circumstances:

Obviously, we cannot confirm that this is the cause of seal failure in every hot wort application, but we believe it is a sound theory based on what we've seen. We can offer the following solutions to the problem:


We hope that this helps to answer some of the questions we've received regarding seal failures. Of course, we would be even happier if we can sell you a SP pump to solve your problem, but we hope just knowing how it happens will help to reduce seal failures on your existing pumps. We will be happy to answer any questions. Please direct e-mail to applications@dairyeng.com.
March 10, 1997